Operation
Starting the Engine
1. Check the oil and fuel levels.
2. Disconnect all electrical loads from the genera-
tor.
3. Open the fuel shut off valve.
Pre-Start Preparation
NOTE: The following procedures are to be
completed each time the generator is started.
1. Before starting the generator, check to make
sure there are no loose or missing parts.
WARNING
The generator must not be operated if all facto-
ry installed heat shields are not in place. Failure
to comply may result in the fuel tank over heat-
ing which could cause personal injury from fire.
4. Pull out choke (if starting a cold engine).
5. Flip ON/OFF switch to the ON position
6. Pull starter rope with a fast steady pull.
Starter
Rope
Handle
7. As engine warms up return choke back to open
position
CAUTION
Allow the generator to run for 5 minutes each
time it is restarted before applying load. This
will let the engine and generator stabilize.
DANGER
Provide adequate ventilation for
toxic exhaust gases and cooling air
flow.
Do not start or run the generator in
and enclosed area, even if windows
or doors are open.
Engines give off carbon monoxide, a
odorless, colorless, poison gas.
Breathing carbon monoxide can
cause nausea, fainting or death.
Applying Load
This generator has been pre-tested and adjusted
at the factory to handle its rated load.
Apply load only after the generator is running
and has warmed up for 5 minutes.
Voltage is regulated by the speed of the engine
which is adjusted at the factory for correct out-
put. Readjusting will void the warranty.